RAB Series Reverse Acting Brake RAB-40B24-M30, RAB-40, 24 VDC, 30 mm Bore, 36 Nm

$1,157.57

Out of Stock - Contact Us for Lead Time

  • RAB-40B24-M30
  • RAB Reverse Acting Brake
  • Model: RAB-40
  • Voltage: 24 VDC
  • Static Torque: 36 N·m
  • Bore: 30 mm

SPECIFICATIONS

Part Number RAB-40B24-M30
Model RAB-40
Series RAB Series Reverse Acting Brake
Type Permanent Magnet Power-Off Brake
Static Torque 36 N·m (318.6 lb. in.)
Coil Voltage 24 VDC
Bore 30 mm
Outside Diameter 125 mm (4.92 in.)
Engagement Static or dynamic
Backlash Zero
Wiring Red lead +, black lead −
Insulation UL Class F
Compliance RoHS, REACH
Factory Description Reverse acting brake

SERIES DESCRIPTION

RAB Series reverse acting brakes (Regal Rexnord / Thomson) are compact, permanent magnet power-off brakes. A permanent magnet holds the armature against the friction face so the brake is engaged whenever power is off; applying 24 VDC to the coil cancels the magnetic field and releases the brake. The design gives zero backlash and high torque for its size, making it a common holding brake for servo motors, robotics and vertical axes. Eight sizes, RAB-13 to RAB-60, cover 1 to 140 N·m.

FEATURES

  • Fail-safe — engages automatically on power loss.
  • Permanent magnet engagement — zero backlash for precise holding.
  • Static or dynamic engagement (holding or emergency stopping).
  • Field fixed design; compact axial length.
  • 24 VDC coil, UL Class F insulation; red lead positive, black lead negative.
  • RoHS and REACH compliant.

SELECTION PROCEDURE

  1. Size by torque: Pick a size whose static torque exceeds the holding torque the load requires at the brake shaft.
  2. Match the bore: Each part number is one metric bore.
  3. Observe polarity: The coil is polarized; connect red to + and black to − or the brake will not release.

TYPICAL APPLICATIONS

Servo and stepper motor holding brakes, robotics, vertical axes and Z-axis lifts, medical equipment, automated guided vehicles and packaging machinery.

HOW TO ORDER

  • Specify Part Number: Order RAB-40B24-M30 (RAB-40, 24 VDC, 30 mm bore).
  • Verify Coil Voltage: Confirm your supply provides 24 VDC, with correct polarity (red +, black −).
  • Fail-Safe Operation: The brake holds whenever power is off; energize the coil to release it.
  • Lead Time: Built to order; contact us for current availability.
5138237 e1722390771778

Got a Question? We’re Here To Help