SPECIFICATIONS
| Part Number | 0117-1012 |
| Model | SL-42 |
| Series | Warner Electric SL Series |
| Type | Power-On Clutch |
| Rated Static Torque | 250 lb. in. (28.25 N·m) |
| Typical Torque | 225 lb. in. out of the box; 275 lb. in. after burnishing |
| Coil Voltage | 90 VDC |
| Coil Current | .124 A |
| Coil Resistance | 722 Ω |
| Bore | 1″ |
| Bore Note | The catalog lists the 1″ bore for the rotor only on this size; contact us to confirm the armature hub fit for your application. |
| Keyway | .251-.253 in. wide; 1.113-1.121 in. key height plus bore |
| Electrical Connection | Screw terminals |
| Torque Build-Up Time | 45 ms to 80%; 70 ms to 100% |
| Torque Decay Time | 50 ms to 10% (with suppression diode) |
| Inertia | rotor 2.50, armature & hub 2.30 lb. in.² |
| Weight | 85 oz. (5.31 lb.) |
| Air Gap | .005-.020 in. (.127-.508 mm), set at the factory |
| Armature Hub | Keyed |
| Mounting | Shaft mounted; restrain the field with a loose-fitting pin through the anti-rotation tab |
| Dimensions (in., see drawing) | A = 3.82 max; B = 0.32; C = 1.56 max; D = 4.27 max; E = 1.374; G = 2.05; H = 1.625; I = 0.645 max; J = 0.19 min; K = 2.5; L = 2.312; O = 0.187 |
| Agency | Coil built with UL recognized materials; RoHS compliant |
| Factory Description | SL-42 90VDC 1 CLUTCH T |
| Catalog | Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874) | |
| Catalog | Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630) |
SERIES DESCRIPTION
Warner Electric SL Series power-on clutches (formerly Inertia Dynamics) mount on one shaft and drive a second, parallel shaft through a pulley, gear or sprocket on the armature hub. Energizing the stationary coil pulls the armature against the rotor to transmit torque; removing power lets the zero-backlash spring pull it clear with no residual drag. Nine sizes, SL-08 to SL-42, cover 2.5 to 250 lb. in. BSL models add ball bearings on the armature and field for higher speeds and side loads.
FEATURES
- Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
- Zero-backlash armature with spring release for precise, repeatable engagement.
- Stationary field — no slip rings or brushes to wear out.
- Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
- UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
- Sizes 08-42 with inch or metric bores; lead wires on small sizes, screw terminals on 30 and 42.
SELECTION PROCEDURE
- Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
- Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
- Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
- Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.
TYPICAL APPLICATIONS
Office machines, printers, copiers, ATMs, vending equipment, packaging and labeling machines, conveyors and other light-duty drives.
HOW TO ORDER
- Specify Part Number: Order 0117-1012 (SL-42, 90 VDC, 1″ bore).
- Verify Coil Voltage: Confirm your supply provides 90 VDC filtered, full-wave DC; half-wave DC gives lower torque.
- Anti-Rotation: Restrain the field with a loose-fitting pin or bracket through the anti-rotation tab. Do not bolt the tab solid, which preloads the bearings.
- Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
- Arc Suppression: Fit a diode across the coil; published decay times assume one.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us