Warner Electric 0317-1912 BSL-42 Ball Bearing Power-On Clutch, 90 VDC, 7/8″ Bore, Screw Terminals

$1,988.15

Lead time - 1 Week +

  • 0317-1912
  • BSL Series Ball Bearing Power-On Clutch
  • Model: BSL-42
  • Voltage: 90 VDC
  • Static Torque: 250 lb.in. (20.8 lb.ft., 28.2 N·m)
  • Bore: 7/8″

SPECIFICATIONS

Part Number 0317-1912
Model BSL-42
Series Warner Electric BSL Series
Type Ball Bearing Power-On Clutch
Rated Static Torque 250 lb. in. (28.25 N·m)
Typical Torque 225 lb. in. out of the box; 275 lb. in. after burnishing
Coil Voltage 90 VDC
Coil Current .124 A
Coil Resistance 722 Ω
Bore 7/8″
Keyway .1885-.1905 in. wide; .962-.970 in. key height plus bore
Electrical Connection Screw terminals
Torque Build-Up Time 45 ms to 80%; 70 ms to 100%
Torque Decay Time 50 ms to 10% (with suppression diode)
Inertia rotor 2.250, armature & hub 4.990 lb. in.²
Weight 94 oz. (5.88 lb.)
Air Gap .005-.020 in. (.127-.508 mm), set at the factory
Output Hub 3 holes 1/4-20 UNC-2B on 3.500 in. bolt circle for your pulley or sprocket
Mounting Shaft mounted; restrain the field with a loose-fitting pin through the anti-rotation tab
Dimensions (in., see drawing) A = 3.350 max; B = .000 max; C = .267; D = 4.015 max; E = 2.999; G = 1.405; H = .673; I = .645 max; J = .188 min; K = 2.500; L = 2.216; N = .383; O = 1.810; P = 4.270 max
Agency Coil built with UL recognized materials; RoHS compliant
Factory Description BSL-42 90VDC 7/8 CL

 

pdf icon 1
Catalog Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874)
Catalog Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630)

SERIES DESCRIPTION

Warner Electric SL Series power-on clutches (formerly Inertia Dynamics) mount on one shaft and drive a second, parallel shaft through a pulley, gear or sprocket on the armature hub. Energizing the stationary coil pulls the armature against the rotor to transmit torque; removing power lets the zero-backlash spring pull it clear with no residual drag. Nine sizes, SL-08 to SL-42, cover 2.5 to 250 lb. in. BSL models add ball bearings on the armature and field for higher speeds and side loads.

FEATURES

  • Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
  • Zero-backlash armature with spring release for precise, repeatable engagement.
  • Stationary field — no slip rings or brushes to wear out.
  • Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
  • UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
  • Sizes 08-42 with inch or metric bores; lead wires on small sizes, screw terminals on 30 and 42.

SELECTION PROCEDURE

  1. Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
  2. Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
  3. Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
  4. Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.

TYPICAL APPLICATIONS

Office machines, printers, copiers, ATMs, vending equipment, packaging and labeling machines, conveyors and other light-duty drives.

HOW TO ORDER

  • Specify Part Number: Order 0317-1912 (BSL-42, 90 VDC, 7/8″ bore).
  • Verify Coil Voltage: Confirm your supply provides 90 VDC filtered, full-wave DC; half-wave DC gives lower torque.
  • Anti-Rotation: Restrain the field with a loose-fitting pin or bracket through the anti-rotation tab. Do not bolt the tab solid, which preloads the bearings.
  • Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
  • Arc Suppression: Fit a diode across the coil; published decay times assume one.
5138237 e1722390771778

Got a Question? We’re Here To Help