Warner Electric 0710-1311 SO-11 Power-On Clutch Coupling, 90 VDC, 1/4″ Bore, Lead Wires

$339.94

Lead time - 1 Week +

  • 0710-1311
  • SO Series Power-On Clutch Coupling
  • Model: SO-11
  • Voltage: 90 VDC
  • Static Torque: 6 lb. in.
  • Bore: 1/4″

SPECIFICATIONS

Part Number 0710-1311
Model SO-11
Series Warner Electric SO Series
Type Power-On Clutch Coupling
Rated Static Torque 6 lb. in. (0.68 N·m)
Typical Torque 5 lb. in. out of the box; 8 lb. in. after burnishing
Coil Voltage 90 VDC
Coil Current .047 A
Coil Resistance 1930 Ω
Bore 1/4″
Shaft Retention Set screws (no keyway)
Electrical Connection Lead wires, 12 in.
Torque Build-Up Time 7.2 ms to 80%; 10.5 ms to 100%
Torque Decay Time 11 ms to 10% (with suppression diode)
Inertia rotor .0058, armature & hub .0024 lb. in.²
Weight 3.2 oz. (0.20 lb.)
Air Gap .005-.020 in. (.127-.508 mm), set by the customer at installation
Mounting Rotor and field on the input shaft, armature hub on the load shaft; hold shaft concentricity within .005 in. T.I.R.
Dimensions (in., see drawing) A = 1.168 max; B = .933; C = .777; D = .147; E = 1.160 max; G = .380 max; H = .122 min; I = .875; J = .585; L = .307; M = .093; O = .687
Agency Coil built with UL recognized materials; RoHS compliant
Factory Description SO-11 90 VDC 1/4 CLUTCH CPLG

 

pdf icon 1
Catalog Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874)
Catalog Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630)

SERIES DESCRIPTION

Warner Electric SO Series power-on clutch couplings connect two in-line shafts. The rotor and field go on the input shaft and the armature hub on the load shaft; energizing the coil couples the shafts and removing power releases them with no residual drag. Sizes SO-08 to SO-42 cover 2.5 to 250 lb. in.

FEATURES

  • Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
  • Zero-backlash armature with spring release for precise, repeatable engagement.
  • Stationary field — no slip rings or brushes to wear out.
  • Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
  • UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
  • In-line coupling — no pulley or belt needed between shafts.

SELECTION PROCEDURE

  1. Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
  2. Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
  3. Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
  4. Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.
  5. Shaft alignment: Hold concentricity within .005 in. T.I.R. and set the air gap at installation.

TYPICAL APPLICATIONS

Motor-to-reducer and shaft-to-shaft couplings on business machines, medical equipment, packaging, and light conveyors.

HOW TO ORDER

  • Specify Part Number: Order 0710-1311 (SO-11, 90 VDC, 1/4″ bore).
  • Verify Coil Voltage: Confirm your supply provides 90 VDC filtered, full-wave DC; half-wave DC gives lower torque.
  • Align the Shafts: The rotor/field half mounts on the input shaft and the armature half on the load shaft; hold concentricity within .005 in. T.I.R. and set the air gap at installation.
  • Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
  • Arc Suppression: Fit a diode across the coil; published decay times assume one.