SPECIFICATIONS
| Part Number | 0714-1511 |
| Model | SO-22 |
| Series | Warner Electric SO Series |
| Type | Power-On Clutch Coupling |
| Rated Static Torque | 50 lb. in. (5.65 N·m) |
| Typical Torque | 40 lb. in. out of the box; 60 lb. in. after burnishing |
| Coil Voltage | 90 VDC |
| Coil Current | .079 A |
| Coil Resistance | 1140 Ω |
| Bore | 3/8″ |
| Keyway | .094-.097 in. wide; .417-.427 in. key height plus bore |
| Electrical Connection | Lead wires, 18 in. |
| Torque Build-Up Time | 27 ms to 80%; 42 ms to 100% |
| Torque Decay Time | 20 ms to 10% (with suppression diode) |
| Inertia | rotor .215, armature & hub .070 lb. in.² |
| Weight | 20 oz. (1.25 lb.) |
| Air Gap | .005-.020 in. (.127-.508 mm), set by the customer at installation |
| Mounting | Rotor and field on the input shaft, armature hub on the load shaft; hold shaft concentricity within .005 in. T.I.R. |
| Dimensions (in., see drawing) | A = 1.989 max; B = 1.578; C = 1.423; D = .281; E = 2.260 max; G = .442 max; H = .170 min; I = 1.515; J = 1.160; L = .510; M = .115; N = .117; O = 1.005 |
| Agency | Coil built with UL recognized materials; RoHS compliant |
| Factory Description | SO-22 90VDC 3/8 CL |
| Catalog | Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874) | |
| Catalog | Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630) |
SERIES DESCRIPTION
Warner Electric SO Series power-on clutch couplings connect two in-line shafts. The rotor and field go on the input shaft and the armature hub on the load shaft; energizing the coil couples the shafts and removing power releases them with no residual drag. Sizes SO-08 to SO-42 cover 2.5 to 250 lb. in.
FEATURES
- Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
- Zero-backlash armature with spring release for precise, repeatable engagement.
- Stationary field — no slip rings or brushes to wear out.
- Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
- UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
- In-line coupling — no pulley or belt needed between shafts.
SELECTION PROCEDURE
- Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
- Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
- Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
- Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.
- Shaft alignment: Hold concentricity within .005 in. T.I.R. and set the air gap at installation.
TYPICAL APPLICATIONS
Motor-to-reducer and shaft-to-shaft couplings on business machines, medical equipment, packaging, and light conveyors.
HOW TO ORDER
- Specify Part Number: Order 0714-1511 (SO-22, 90 VDC, 3/8″ bore).
- Verify Coil Voltage: Confirm your supply provides 90 VDC filtered, full-wave DC; half-wave DC gives lower torque.
- Align the Shafts: The rotor/field half mounts on the input shaft and the armature half on the load shaft; hold concentricity within .005 in. T.I.R. and set the air gap at installation.
- Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
- Arc Suppression: Fit a diode across the coil; published decay times assume one.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us