Warner Electric 1112-4411 FB-17 Power-On Brake, 120 VAC, 5/16″ Bore, Lead Wires

$472.78

Lead time - 1 Week +

  • 1112-4411
  • FB Series Power-On Brake
  • Model: FB-17
  • Voltage: 120 VAC
  • Static Torque: 15 lb.in. (1.25 lb.ft., 1.69 N·m)
  • Bore: 5/16″

SPECIFICATIONS

Part Number 1112-4411
Model FB-17
Series Warner Electric FB Series
Type Power-On Brake
Rated Static Torque 15 lb. in. (1.70 N·m)
Typical Torque 12 lb. in. out of the box; 20 lb. in. after burnishing
Coil Voltage 120 VAC
Rectifier Internal (AC input); do not Hi-Pot test
Bore 5/16″
Keyway .0625-.0655 in. wide; .347-.352 in. key height plus bore
Electrical Connection Lead wires, 12 in.
Torque Build-Up Time 10 ms to 80%; 14 ms to 100%
Torque Decay Time 14 ms to 10% (with suppression diode)
Inertia armature & hub .031 lb. in.²
Weight 11 oz. (0.69 lb.)
Air Gap .005-.020 in. (.127-.508 mm), set by the customer at installation
Mounting Flange mount: (4) .186 in. min. holes on 2.125 in. pitch circle; 2.436 in. pilot; 1.943 in. max. square flange
Dimensions (in., see drawing) A = 1.269 max; B = .848; C = 1.780 max; F = .064 max; G = .751; H = 1.943 max; I = 2.436; J = 2.125; M = 1.190 max; N = .115
Agency Coil built with UL recognized materials; RoHS compliant
Factory Description FB-17 120VAC 5/16 BK

 

pdf icon 1
Catalog Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874)
Catalog Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630)

SERIES DESCRIPTION

Warner Electric FB Series power-on brakes (formerly Inertia Dynamics) are flange-mounted friction brakes for stopping and holding light loads. The field bolts to a bulkhead and the armature hub mounts on the load shaft; energizing the coil pulls the armature against the field to stop and hold the load, and removing power releases it with no residual drag. Sizes FB-08 to FB-42 cover 2.5 to 250 lb. in.

FEATURES

  • Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
  • Zero-backlash armature with spring release for precise, repeatable engagement.
  • Stationary field — no slip rings or brushes to wear out.
  • Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
  • UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
  • Flange mounted with a piloted field and four mounting holes.

SELECTION PROCEDURE

  1. Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
  2. Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
  3. Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
  4. Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.
  5. Power-on, not fail-safe: FB brakes hold only while energized. For holding on power loss, use a spring-set or permanent-magnet brake.

TYPICAL APPLICATIONS

Indexing and positioning drives, business machines, medical equipment, packaging and conveyor stops.

HOW TO ORDER

  • Specify Part Number: Order 1112-4411 (FB-17, 120 VAC, 5/16″ bore).
  • Verify Coil Voltage: Confirm your supply provides 120 VAC. The unit has an internal rectifier.
  • Prepare the Mounting Surface: Keep the mounting face square to the shaft within .005 in. T.I.R. at the bolt circle and the pilot concentric with the shaft within .010 in. T.I.R.
  • Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
  • Arc Suppression: Fit a diode across the coil; published decay times assume one.
5138237 e1722390771778