SPECIFICATIONS
| Part Number | 1701-6221 |
| Model | FSB001 |
| Series | Warner Electric FSB Series |
| Type | Spring Applied (Power-Off) Brake |
| Static Torque | 1 lb. in. (0.11 N·m) |
| Coil Voltage | 220 VAC |
| Bore | 3/16″ |
| Coil Data | Contact us for coil current and resistance at this voltage |
| Hub Style | Square Drive |
| Shaft Retention | Set screws (no keyway) |
| Electrical Connection | Lead wires, 12 in. |
| Maximum Speed | 9,000 RPM |
| Inertia (Armature & Hub) | .0004 lb. in.² |
| Weight | 2 oz. (0.12 lb.) |
| Air Gap | Set at the factory |
| Mounting | Flange mount: (3) K holes on the J pitch circle, H pilot; hold mounting face square to the shaft within .005 in. T.I.R. |
| Dimensions (in., see drawing) | A = .890; B = .710; C = .072; D = .510; E = 1.485; F = .320; G = .280; H = 1.375; I = 12.0; J = 1.180; K = .113; L = 3/8 |
| Agency | Coil built with UL recognized materials; RoHS compliant |
| Factory Description | FSB-001 220VAC 3/16 BK |
| Catalog | Warner Electric Spring Applied Friction Brakes FSB/FSBR Catalog (P-8997) | |
| Catalog | Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874) |
SERIES DESCRIPTION
Warner Electric FSB Series spring applied brakes (formerly Inertia Dynamics) are flange-mounted, fail-safe brakes that decelerate or hold a load whenever power is removed. Compression springs clamp the friction disc between the armature and pressure plate; energizing the coil pulls the armature away so the shaft turns freely. Seven sizes cover 1 to 100 lb. in. static torque with square, hex or zero-backlash hubs.
FEATURES
- Fail-safe — engages automatically on power loss.
- Compact flange mount for servo and stepper motors.
- Zero-backlash hubs available on sizes 007-050 for precise positioning.
- Air gap set at the factory; no adjustment needed.
- 12, 24, 90 VDC and 120 VAC coils; metric bores available.
- UL recognized coil materials; RoHS compliant.
SELECTION PROCEDURE
- Size by torque: Pick a size whose static torque exceeds the holding or stopping torque the load requires.
- Check speed and cycle rate: Stay within the maximum input RPM and the allowable cycles per minute for your load inertia.
- Choose the hub: Hex drive is standard; choose zero backlash where positioning accuracy matters.
- Mounting: Keep the mounting face square to the shaft within .005 in. T.I.R.
TYPICAL APPLICATIONS
Servo and stepper motor holding brakes, robotics, medical equipment, packaging machinery, automated guided vehicles and conveyors.
HOW TO ORDER
- Specify Part Number: Order 1701-6221 (FSB001, 220 VAC, 3/16″ bore).
- Verify Coil Voltage: Confirm your supply provides 220 VAC. The brake has an internal rectifier.
- Fail-Safe Operation: Springs apply the brake whenever power is off; energize the coil to release it.
- Burnish for Full Torque: Slip the engaged brake (coil off) for 1-3 minutes at 60-200 RPM, ideally in its final location, to reach full rated torque.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us



