Warner Electric 1904-2521 FSBR015 Spring Applied Brake, 24 VDC, 3/8″ Bore

$559.51

Lead time - 1 Week +

  • 1904-2521
  • FSBR Spring Applied Brake
  • Model: FSBR015
  • Voltage: 24 VDC
  • Static Torque: 15 lb. in.
  • Bore: 3/8″

SPECIFICATIONS

Part Number 1904-2521
Model FSBR015
Series Warner Electric FSBR Series
Type Reverse Mounted Spring Applied (Power-Off) Brake
Static Torque 15 lb. in. (1.70 N·m)
Coil Voltage 24 VDC
Coil Current .369 A
Coil Resistance 65.1 Ω
Bore 3/8″
Hub Style Hex Drive
Keyway .094-.097 in. wide; .417-.427 in. key height plus bore
Electrical Connection Lead wires, 12 in.
Maximum Speed 7,500 RPM
Inertia (Armature & Hub) .0133 lb. in.²
Weight 12 oz. (0.75 lb.)
Air Gap Set at the factory
Mounting Reverse mounted: install the hub on the shaft first, then mount the brake over it with (4) K screws on the J pitch circle. Hold mounting surface square within .005 in. T.I.R.
Dimensions (in., see drawing) A = .062; B = 1.200; C = .600; E = 2.400; F = .605; G = .945; H = 3.235; I = 12.0; J = 2.844; K = .187; L = 5/8
Agency Coil built with UL recognized materials; RoHS compliant
Factory Description FSBR-015 24VDC 3/8 BK

 

pdf icon 1
Catalog Warner Electric Spring Applied Friction Brakes FSB/FSBR Catalog (P-8997)
Catalog Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874)

SERIES DESCRIPTION

Warner Electric FSBR Series reverse-mounted spring applied brakes are built for applications with minimal axial space or short motor shaft extensions. The hub goes on the shaft first, then the brake mounts over the hub. Springs apply the brake whenever power is off; energizing the coil releases it. Five sizes cover 7 to 100 lb. in.

FEATURES

  • Fail-safe — engages automatically on power loss.
  • Short axial length for tight spaces and short shafts.
  • Hex drive hub with keyed bore.
  • Air gap set at the factory.
  • UL recognized coil materials; RoHS compliant.

SELECTION PROCEDURE

  1. Size by torque: Pick a size whose static torque exceeds the load requirement.
  2. Hub position: Install the hub at dimension “A” from the mounting surface before fitting the brake.
  3. Mounting: Keep the mounting surface square within .005 in. and the holes concentric within .020 in. T.I.R.

TYPICAL APPLICATIONS

Servo and stepper motors with short shafts, robotics, medical equipment and compact machinery.

HOW TO ORDER

  • Specify Part Number: Order 1904-2521 (FSBR015, 24 VDC, 3/8″ bore).
  • Verify Coil Voltage: Confirm your supply provides 24 VDC. Use filtered DC; a diode across the coil protects the switch.
  • Fail-Safe Operation: Springs apply the brake whenever power is off; energize the coil to release it.
  • Hub Position: Install the hub dimension “A” from the mounting surface before mounting the brake.
  • Burnish for Full Torque: Slip the engaged brake (coil off) for 1-3 minutes at 60-200 RPM, ideally in its final location, to reach full rated torque.