SPECIFICATIONS
| Part Number | 6910-448-017 |
| Model | MCS-204 |
| Type | Remote/analog tension control module |
| Input power | 26-28 VDC +/-10%, 1.5 A max with single brake, 3.0 A max with dual brake; from single or dual MCS-166 power supplies |
| Output | Forward: 0-24 VDC pulse-width modulated, 3 A max. Reverse (anti-residual): 0 to 1.8 VDC into 10 ohm load, or 0 to 180 mA max |
| Control type | Open loop; output proportional to input signal |
| Control inputs | Local torque knob, remote/roll-follower potentiometer, voltage source, current source (current loop with shunt resistor), analog photoelectric sensor via Iso-verter |
| Auxiliary inputs | Brake On (full 24 VDC output, active low); Brake Off (removes power, applies anti-residual, active low); switch closure or NPN open collector, rated 20 VDC min / 0.02 A max |
| Front-panel adjustments | Zero Adjust; Torque Adjust/Span |
| Fuse | 3 A, fast-acting, type 3AG, DC input |
| Protection | Internal short-circuit protection on driver output stage; reverse polarity protection on DC input |
| Ambient temperature | +32 F to +120 F (0 C to +49 C) |
| Enclosure | Control chassis considered NEMA 1 |
| Housing variants | Panel mount housing 6910-448-015; Wall/Shelf mount housing 6910-448-016 |
| Mounting | Panel cutout 3-5/16 x 6-1/16 in; wall/shelf housings join with MCS-166 |
| Compatible brakes | TB style electric tension brakes (single or dual) |
| Spare boards | Logic board 6910-448-022; Output/driver board 6910-448-023 |
| Factory Description | T CTRL REMOTE ANALOG MCS204 |
| Manual | Warner Electric MCS-166 / MCS-203 / MCS-204 Tension Control System (P-0257) | |
| Manual | Warner Electric MCS-166 / MCS-207 / MCS-208 Pneumatic Tension Control (P-276) |
SERIES DESCRIPTION
Warner Electric tension controls keep web and strand tension constant on unwind and rewind stands by adjusting the torque of an electric or air-actuated tension brake. Systems pair a power supply with a control module — open-loop manual or analog controls, or closed-loop dancer controls — and drive Warner TB, ATTB, Electro Disc, Air Disc and magnetic particle brakes.
FEATURES
- Open-loop and closed-loop control options.
- Modular power supply and control modules.
- Panel or wall/shelf mounting.
- Drives Warner tension brakes from small TB units to Electro Disc and Air Disc systems.
SELECTION PROCEDURE
- Pick the control type: Manual/analog (open loop) for simple unwinds, or dancer (closed loop) for automatic tension control.
- Match the brake: Electric (24 VDC or 48 VDC) or pneumatic brakes need the matching control and power supply.
- Need help? Send us your web material, roll sizes and speeds and we will help size the system.
TYPICAL APPLICATIONS
Unwind and rewind stands, printing and converting lines, wire and cable payoffs, labeling and packaging machinery.
HOW TO ORDER
- Specify Part Number: Order 6910-448-017 (MCS-204).
- Power Supply: Order an MCS-166 power supply (6910-448-013); use two for dual-brake applications.
- Housing: Panel mount housing 6910-448-015 or wall/shelf housing 6910-448-016.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us