SPECIFICATIONS
| Part Number | 6910-448-026 |
| Model | TCS-210 |
| Type | Dancer tension control |
| Function | Automatic web tension control via dancer roll and position sensor (closed loop) |
| Input power | 48 VDC, 1.6 A continuous / 6 A intermittent (from TCS-167 power supply) |
| Output (per magnet) | 0-270 mA running; 270-500 mA stopping |
| Mounting | Cabinet mount (exposed wiring) or wall/shelf with conduit entrance |
| Compatible brakes | Electro Disc or other electromagnetic tension brakes |
| Factory Description | TENSION CTRL DANCER TCS-210 |
| Manual | Warner Electric TCS-167 / TCS-210 / TCS-220 Tension Brake Control System (P-261) |
SERIES DESCRIPTION
Warner Electric tension controls keep web and strand tension constant on unwind and rewind stands by adjusting the torque of an electric or air-actuated tension brake. Systems pair a power supply with a control module — open-loop manual or analog controls, or closed-loop dancer controls — and drive Warner TB, ATTB, Electro Disc, Air Disc and magnetic particle brakes.
FEATURES
- Open-loop and closed-loop control options.
- Modular power supply and control modules.
- Panel or wall/shelf mounting.
- Drives Warner tension brakes from small TB units to Electro Disc and Air Disc systems.
SELECTION PROCEDURE
- Pick the control type: Manual/analog (open loop) for simple unwinds, or dancer (closed loop) for automatic tension control.
- Match the brake: Electric (24 VDC or 48 VDC) or pneumatic brakes need the matching control and power supply.
- Need help? Send us your web material, roll sizes and speeds and we will help size the system.
TYPICAL APPLICATIONS
Unwind and rewind stands, printing and converting lines, wire and cable payoffs, labeling and packaging machinery.
HOW TO ORDER
- Specify Part Number: Order 6910-448-026 (TCS-210).
- Power Supply: Order a TCS-167 power supply (6910-448-025).