SPECIFICATIONS
| Part Number | 6910-448-067 |
| Model | MCS-208 |
| Type | Remote/analog control (pneumatic) |
| Input power | 26 +/- 4 VDC, 0.5 A max (MCS-166 power supply) |
| Outputs | 1-5 mA, 4-20 mA, 10-50 mA, 1-9 VDC (standard transducer accepts 4-20 mA) |
| Control type | Open loop; output signal proportional to input, converted to brake air pressure by electro-pneumatic transducer |
| Operating modes | Local torque adjust (front-panel knob); remote torque adjust (remote pot); roll follower (external pot); current loop 1-5, 4-20, 10-50 mA; voltage input 1-9 VDC |
| Auxiliary inputs | Brake On (max output), Brake Off (min output); switch closure or NPN open collector, 20 VDC min / 0.02 A max |
| Front-panel adjustments | Zero Adjust; Torque Adjust/Span |
| Fuse | 1/2 A, fast acting, 250 V |
| Protection | Reverse voltage protection on DC power connections |
| Ambient temperature | +32 F to +120 F (0 C to +49 C) |
| Mounting | Wall/shelf (joinable housings) or panel mount (3-5/16 x 6-1/16 in cutout) |
| Compatible components | MCS-166 power supply; electro-pneumatic transducer 6910-101-066; Air Disc pneumatic tension brakes |
| Factory Description | T CTRL ANALOG MCS-208 |
| Manual | Warner Electric MCS-166 / MCS-207 / MCS-208 Pneumatic Tension Control (P-276) |
SERIES DESCRIPTION
Warner Electric tension controls keep web and strand tension constant on unwind and rewind stands by adjusting the torque of an electric or air-actuated tension brake. Systems pair a power supply with a control module — open-loop manual or analog controls, or closed-loop dancer controls — and drive Warner TB, ATTB, Electro Disc, Air Disc and magnetic particle brakes.
FEATURES
- Open-loop and closed-loop control options.
- Modular power supply and control modules.
- Panel or wall/shelf mounting.
- Drives Warner tension brakes from small TB units to Electro Disc and Air Disc systems.
SELECTION PROCEDURE
- Pick the control type: Manual/analog (open loop) for simple unwinds, or dancer (closed loop) for automatic tension control.
- Match the brake: Electric (24 VDC or 48 VDC) or pneumatic brakes need the matching control and power supply.
- Need help? Send us your web material, roll sizes and speeds and we will help size the system.
TYPICAL APPLICATIONS
Unwind and rewind stands, printing and converting lines, wire and cable payoffs, labeling and packaging machinery.
HOW TO ORDER
- Specify Part Number: Order 6910-448-067 (MCS-208).
- System Components: Pair with an MCS-166 power supply (6910-448-013) and the electro-pneumatic transducer kit 6910-101-066.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us