Warner Electric M1114-2411 FB-22 Power-On Brake, 24 VDC, 10 mm Bore, Lead Wires

$527.98

Lead time - 1 Week +

  • M1114-2411
  • FB Series Power-On Brake
  • Model: FB-22
  • Voltage: 24 VDC
  • Static Torque: 50 lb. in.
  • Bore: 10 mm

SPECIFICATIONS

Part Number M1114-2411
Model FB-22
Series Warner Electric FB Series
Type Power-On Brake
Rated Static Torque 50 lb. in. (5.65 N·m)
Typical Torque 40 lb. in. out of the box; 60 lb. in. after burnishing
Coil Voltage 24 VDC
Coil Current .322 A
Coil Resistance 74.6 Ω
Bore 10 mm
Electrical Connection Lead wires, 18 in.
Torque Build-Up Time 27 ms to 80%; 42 ms to 100%
Torque Decay Time 20 ms to 10% (with suppression diode)
Inertia armature & hub .070 lb. in.²
Weight 20 oz. (1.25 lb.)
Air Gap .005-.020 in. (.127-.508 mm), set by the customer at installation
Mounting Flange mount: (4) .160 in. min. holes on 2.500 in. pitch circle; 2.873 in. pilot; 2.322 in. max. square flange
Dimensions (in., see drawing) A = 1.757 max; B = 1.173; C = 2.260 max; F = .096 max; G = 1.001; H = 2.322 max; I = 2.873; J = 2.500; M = 1.005 max; N = .115
Agency Coil built with UL recognized materials; RoHS compliant
Factory Description FB-22 24VDC 10MM BK

 

pdf icon 1
Catalog Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874)
Catalog Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630)

SERIES DESCRIPTION

Warner Electric FB Series power-on brakes (formerly Inertia Dynamics) are flange-mounted friction brakes for stopping and holding light loads. The field bolts to a bulkhead and the armature hub mounts on the load shaft; energizing the coil pulls the armature against the field to stop and hold the load, and removing power releases it with no residual drag. Sizes FB-08 to FB-42 cover 2.5 to 250 lb. in.

FEATURES

  • Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
  • Zero-backlash armature with spring release for precise, repeatable engagement.
  • Stationary field — no slip rings or brushes to wear out.
  • Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
  • UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
  • Flange mounted with a piloted field and four mounting holes.

SELECTION PROCEDURE

  1. Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
  2. Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
  3. Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
  4. Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.
  5. Power-on, not fail-safe: FB brakes hold only while energized. For holding on power loss, use a spring-set or permanent-magnet brake.

TYPICAL APPLICATIONS

Indexing and positioning drives, business machines, medical equipment, packaging and conveyor stops.

HOW TO ORDER

  • Specify Part Number: Order M1114-2411 (FB-22, 24 VDC, 10 mm bore).
  • Verify Coil Voltage: Confirm your supply provides 24 VDC filtered, full-wave DC; half-wave DC gives lower torque.
  • Prepare the Mounting Surface: Keep the mounting face square to the shaft within .005 in. T.I.R. at the bolt circle and the pilot concentric with the shaft within .010 in. T.I.R.
  • Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
  • Arc Suppression: Fit a diode across the coil; published decay times assume one.