SPECIFICATIONS
| Part Number | M1115-2611 |
| Model | FB-26 |
| Series | Warner Electric FB Series |
| Type | Power-On Brake |
| Rated Static Torque | 80 lb. in. (9.04 N·m) |
| Typical Torque | 65 lb. in. out of the box; 90 lb. in. after burnishing |
| Coil Voltage | 24 VDC |
| Coil Current | .374 A |
| Coil Resistance | 64.2 Ω |
| Bore | 15 mm |
| Electrical Connection | Lead wires, 18 in. |
| Torque Build-Up Time | 22 ms to 80%; 40 ms to 100% |
| Torque Decay Time | 30 ms to 10% (with suppression diode) |
| Inertia | armature & hub .320 lb. in.² |
| Weight | 28 oz. (1.75 lb.) |
| Air Gap | .005-.020 in. (.127-.508 mm), set by the customer at installation |
| Mounting | Flange mount: (4) .182 in. min. holes on 3.125 in. pitch circle; 3.499 in. pilot; 2.630 in. max. square flange |
| Dimensions (in., see drawing) | A = 1.815 max; B = 1.300; C = 2.645 max; F = .080 max; G = 1.062; H = 2.630 max; I = 3.499; J = 3.125; M = 1.440 max; N = .150 |
| Agency | Coil built with UL recognized materials; RoHS compliant |
| Factory Description | FB-26 24VDC 15MM BK L |
| Catalog | Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874) | |
| Catalog | Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630) |
SERIES DESCRIPTION
Warner Electric FB Series power-on brakes (formerly Inertia Dynamics) are flange-mounted friction brakes for stopping and holding light loads. The field bolts to a bulkhead and the armature hub mounts on the load shaft; energizing the coil pulls the armature against the field to stop and hold the load, and removing power releases it with no residual drag. Sizes FB-08 to FB-42 cover 2.5 to 250 lb. in.
FEATURES
- Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
- Zero-backlash armature with spring release for precise, repeatable engagement.
- Stationary field — no slip rings or brushes to wear out.
- Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
- UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
- Flange mounted with a piloted field and four mounting holes.
SELECTION PROCEDURE
- Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
- Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
- Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
- Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.
- Power-on, not fail-safe: FB brakes hold only while energized. For holding on power loss, use a spring-set or permanent-magnet brake.
TYPICAL APPLICATIONS
Indexing and positioning drives, business machines, medical equipment, packaging and conveyor stops.
HOW TO ORDER
- Specify Part Number: Order M1115-2611 (FB-26, 24 VDC, 15 mm bore).
- Verify Coil Voltage: Confirm your supply provides 24 VDC filtered, full-wave DC; half-wave DC gives lower torque.
- Prepare the Mounting Surface: Keep the mounting face square to the shaft within .005 in. T.I.R. at the bolt circle and the pilot concentric with the shaft within .010 in. T.I.R.
- Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
- Arc Suppression: Fit a diode across the coil; published decay times assume one.