SPECIFICATIONS
| Part Number | M2104-2341 |
| Model | FSBR015 Manual Release |
| Series | Warner Electric FSBR Series |
| Type | Reverse Mounted Spring Applied Brake with Manual Release Lever |
| Version | Static (parking) – 30 lb. in. static torque |
| Static Torque | 30 lb. in. (3.39 N·m) |
| Coil Voltage | 24 VDC |
| Coil Current | .369 A |
| Coil Resistance | 65.1 Ω |
| Bore | 8 mm |
| Hub Style | Hex Drive |
| Electrical Connection | Lead wires |
| Manual Release | Lever rotates to release the brake mechanically; 3.500 in. lever arm |
| Inertia (Armature & Hub) | .0133 lb. in.² |
| Weight | 34 oz. (2.13 lb.) |
| Mounting | (4) .180 in. holes equally spaced on a 2.844 in. bolt circle; mount with #8 socket head cap screws only; (2) #8-32 set screws |
| Typical Applications | Wheelchairs, carts and scooters, fractional horsepower motors |
| Agency | Coil built with UL recognized materials; RoHS compliant |
| Factory Description | FSBR-015MR 24VDC 8MM BK |
| Catalog | Warner Electric (Inertia Dynamics) Electric Clutches & Brakes Catalog (P-7874) |
SERIES DESCRIPTION
The Warner Electric FSBR015 Manual Release brake is a reverse-mounted spring applied brake with a release lever. Rotating the lever mechanically pulls the armature against the springs so the load can be moved by hand; rotating it back restores braking. An optional microswitch disconnects power to the system while the brake is released. It comes in a 15 lb. in. dynamic version and a 30 lb. in. static parking-brake version.
FEATURES
- Manual release lever for moving the load with power off.
- Optional release switch prevents accidental start-up while released.
- Dynamic (15 lb. in.) or static parking (30 lb. in.) versions.
- Fail-safe spring-applied operation.
SELECTION PROCEDURE
- Choose the version: Dynamic for stopping and holding; static only where a parking brake is needed.
- Use a switch: Warner recommends a switch or other method so the brake is not operated while manually released.
TYPICAL APPLICATIONS
Wheelchairs, three-wheel carts and scooters, and fractional horsepower motors.
HOW TO ORDER
- Specify Part Number: Order M2104-2341 (FSBR015 Manual Release, 24 VDC, 8 mm bore).
- Verify Coil Voltage: Confirm your supply provides 24 VDC. Use filtered DC; a diode across the coil protects the switch.
- Use a Switch: Warner recommends a switch or other method so the brake is not operated while manually released.
- Static Version: The 30 lb. in. static version is a parking brake only; use the 15 lb. in. dynamic version for stopping.
- Burnish for Full Torque: Slip the engaged brake (coil off) for 1-3 minutes at 60-200 RPM, ideally in its final location, to reach full rated torque.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us