SPECIFICATIONS
| Part Number | SF110-M6-24 |
| Model | SF-110 |
| Series | Warner Electric SF Series |
| Type | Stationary Field Clutch for Parallel Shafts (power-on) |
| Static Torque | 6 lb. in. (0.68 N·m) |
| Coil Voltage | 24 VDC |
| Coil Current | .198 A |
| Coil Resistance | 121 Ω |
| Bore | 6 mm |
| Shaft Retention | (2) set screws 90° apart; no keyway |
| Armature Hub | Knurled armature hub, E = .506 in. |
| Electrical Connection | Lead wires, 12 in., UL style 1213/1015/1430, 22 gauge |
| Inertia (Rotor / Armature & Hub) | .0058 / .0029 lb. in.² |
| Response Time (80% build-up / 100% build-up / 10% decay) | 7.2 / 10.5 / 11 ms |
| Weight | 3.2 oz. (0.2 lb.) |
| Air Gap | .018 in., set at the factory |
| Dimensions (in., see drawing) | A = 1.409; B = .147; C = .396; D = 1.160; G = .935; H = .777; I = .380; J = .122; K = .875; L = .585; M = 12.00; O = .087 |
| Agency | UL recognized coil materials; RoHS compliant |
| Factory Description | SF-110 6MM 24VDC CL |
| Catalog | Warner Electric Fractional HP Clutches & Brakes Catalog (P-1630) |
SERIES DESCRIPTION
Warner Electric SF Series stationary field clutches are bearing mounted clutches for parallel shaft applications. The clutch mounts on one shaft and drives a second, parallel shaft through a customer-supplied pulley, sprocket or gear fastened to the armature hub. Energizing the stationary coil pulls the zero-backlash armature against the rotor to transmit torque; removing power releases it with no residual drag. Sizes SF-110, SF-150 and SF-180 cover 6 to 15 lb. in.
FEATURES
- Power-on design — torque only while the coil is energized; no residual drag when power is removed.
- Stationary field — no slip rings or brushes; anti-rotation tab holds the field.
- Zero-backlash armature with spring release for precise, repeatable engagement.
- Bearing mounted; air gap preset at the factory (.018 in.).
- Extended armature hub on SF-150 and SF-180 with (3) #4-40 tapped holes on a .812 in. bolt circle for mounting a pulley or sprocket.
- 12, 24 and 90 VDC coils; UL recognized lead wire; RoHS compliant.
SELECTION PROCEDURE
- Size by torque: Pick a size whose static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
- Match bore and voltage: Each part number is one bore and one coil voltage. Shafts are retained by set screws (no keyway) on these sizes.
- Hold the field: Restrain the anti-rotation tab without side-loading the bearing.
TYPICAL APPLICATIONS
Copiers and printers, packaging machinery, document and mail handling, postal sorters, conveyors, medical equipment and textile machinery.
HOW TO ORDER
- Specify Part Number: Order SF110-M6-24 (SF-110, 24 VDC, 6 mm bore).
- Verify Coil Voltage: Confirm your supply provides 24 VDC. Use filtered DC; a diode across the coil protects the switch.
- Mount the Drive Element: Fasten your pulley, sprocket or gear to the armature hub; it turns with the hub only while the coil is energized.
- Restrain the Field: Hold the anti-rotation tab with a pin or bracket that allows slight float; do not clamp it rigidly.