Warner Electric SF180-516-90 SF-180 Stationary Field Clutch, 90 VDC, 5/16″ Bore

$486.15

Lead time - 1 Week +

  • SF180-516-90
  • SF Series Clutch
  • Model: SF-180
  • Voltage: 90 VDC
  • Static Torque: 15 lb.in. (1.25 lb.ft., 1.69 N·m)
  • Bore: 5/16″

SPECIFICATIONS

Part Number SF180-516-90
Model SF-180
Series Warner Electric SF Series
Type Stationary Field Clutch for Parallel Shafts (power-on)
Static Torque 15 lb. in. (1.70 N·m)
Coil Voltage 90 VDC
Coil Current .066 A
Coil Resistance 1369 Ω
Bore 5/16″
Shaft Retention (2) set screws 90° apart; no keyway
Armature Hub Extended armature hub, E = .622 in., (3) #4-40 tapped holes on a .812 in. BC
Electrical Connection Lead wires, 12 in., UL style 1213/1015/1430, 22 gauge
Inertia (Rotor / Armature & Hub) .061 / .036 lb. in.²
Response Time (80% build-up / 100% build-up / 10% decay) 10 / 14 / 14 ms
Weight 11 oz. (0.69 lb.)
Air Gap .018 in., set at the factory
Dimensions (in., see drawing) A = 1.823; B = .279; C = .250; D = 1.780; G = 1.316; H = 1.060; I = .505; J = .184; K = 1.325; L = .975; M = 12.00; O = .125
Agency UL recognized coil materials; RoHS compliant
Factory Description SF-180 5/16 90VDC CL

 

pdf icon 1
Catalog Warner Electric Fractional HP Clutches & Brakes Catalog (P-1630)

SERIES DESCRIPTION

Warner Electric SF Series stationary field clutches are bearing mounted clutches for parallel shaft applications. The clutch mounts on one shaft and drives a second, parallel shaft through a customer-supplied pulley, sprocket or gear fastened to the armature hub. Energizing the stationary coil pulls the zero-backlash armature against the rotor to transmit torque; removing power releases it with no residual drag. Sizes SF-110, SF-150 and SF-180 cover 6 to 15 lb. in.

FEATURES

  • Power-on design — torque only while the coil is energized; no residual drag when power is removed.
  • Stationary field — no slip rings or brushes; anti-rotation tab holds the field.
  • Zero-backlash armature with spring release for precise, repeatable engagement.
  • Bearing mounted; air gap preset at the factory (.018 in.).
  • Extended armature hub on SF-150 and SF-180 with (3) #4-40 tapped holes on a .812 in. bolt circle for mounting a pulley or sprocket.
  • 12, 24 and 90 VDC coils; UL recognized lead wire; RoHS compliant.

SELECTION PROCEDURE

  1. Size by torque: Pick a size whose static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
  2. Match bore and voltage: Each part number is one bore and one coil voltage. Shafts are retained by set screws (no keyway) on these sizes.
  3. Hold the field: Restrain the anti-rotation tab without side-loading the bearing.

TYPICAL APPLICATIONS

Copiers and printers, packaging machinery, document and mail handling, postal sorters, conveyors, medical equipment and textile machinery.

HOW TO ORDER

  • Specify Part Number: Order SF180-516-90 (SF-180, 90 VDC, 5/16″ bore).
  • Verify Coil Voltage: Confirm your supply provides 90 VDC. Use filtered DC; a diode across the coil protects the switch.
  • Mount the Drive Element: Fasten your pulley, sprocket or gear to the armature hub; it turns with the hub only while the coil is energized.
  • Restrain the Field: Hold the anti-rotation tab with a pin or bracket that allows slight float; do not clamp it rigidly.
5138237 e1722390771778