SPECIFICATIONS
| Part Number | SFP180-38-24 |
| Model | SFP-180 |
| Series | Warner Electric SFP Series |
| Type | Pulley Clutch |
| Rated Static Torque | 15 lb. in. (1.70 N·m) |
| Typical Torque | 12 lb. in. out of the box; 20 lb. in. after burnishing |
| Coil Voltage | 24 VDC |
| Coil Current | .289 A |
| Coil Resistance | 83.1 Ω |
| Bore | 3/8″ |
| Shaft Retention | Set screws (no keyway) |
| Electrical Connection | Lead wires, 12 in. |
| Torque Build-Up Time | 10 ms to 80%; 14 ms to 100% |
| Torque Decay Time | 14 ms to 10% (with suppression diode) |
| Inertia | rotor .052, armature & hub .095 lb. in.² |
| Weight | 26 oz. (1.62 lb.) |
| Air Gap | .005-.020 in. (.127-.508 mm), set at the factory |
| Output Hub | 3 holes 8-32 UNC-2B on 1.437 in. bolt circle for your pulley or sprocket |
| Mounting | Shaft mounted; restrain the field with a loose-fitting pin through the anti-rotation tab |
| Dimensions (in., see drawing) | A = 2.515 max; B = 0.304 max; C = 0.500; D = 1.755 max; E = 0.9985; G = 1.290; H = 0.193; I = 0.505 max; J = 0.184 min; K = 1.325; L = 0.975; N = 0.315; O = 0.875; P = 1.620 max |
| Agency | Coil built with UL recognized materials; RoHS compliant |
| Factory Description | SFP-180 3/8 24VDC CL |
| Catalog | Warner Electric Fractional HP Clutches/Brakes Catalog (P-1630) |
SERIES DESCRIPTION
Warner Electric SFP Series pulley clutches are pre-assembled SF power-on clutches with a bearing-mounted field/rotor and a bearing-mounted output hub that accepts your pulley or sprocket. Slide the unit onto a driving or driven shaft, bolt on the drive component and connect to the load by chain or belt.
FEATURES
- Power-on design — torque is produced only while the coil is energized; no residual drag when power is removed.
- Zero-backlash armature with spring release for precise, repeatable engagement.
- Stationary field — no slip rings or brushes to wear out.
- Asbestos-free friction material for long life and quiet operation; corrosion-protected parts.
- UL recognized coil materials; RoHS compliant; 100% Hi-Pot tested.
- Pre-assembled with the air gap set at the factory.
- Output hub with three tapped holes on a bolt circle for your pulley or sprocket.
SELECTION PROCEDURE
- Size by torque: Pick a size whose rated static torque exceeds the torque your load requires, with a service factor for inertia and cycle rate.
- Match the bore and voltage: Each part number is one bore and one coil voltage; 12, 24 and 90 VDC coils are standard.
- Plan for burnishing: Units reach rated torque after burnishing; out of the box they typically produce somewhat less.
- Use DC power: Filtered full-wave DC gives full torque; a diode across the coil protects the switch.
TYPICAL APPLICATIONS
Conveyors, packaging and labeling machines, feeders, and other belt or chain drives that need on-demand engagement.
HOW TO ORDER
- Specify Part Number: Order SFP180-38-24 (SFP-180, 24 VDC, 3/8″ bore).
- Verify Coil Voltage: Confirm your supply provides 24 VDC filtered, full-wave DC; half-wave DC gives lower torque.
- Anti-Rotation: Restrain the field with a loose-fitting pin or bracket through the anti-rotation tab. Do not bolt the tab solid, which preloads the bearings.
- Burnish for Full Torque: New units typically deliver less than rated torque until burnished. Energize at 30-40% of rated voltage and slip the unit for 2-3 minutes, ideally in its final location.
- Arc Suppression: Fit a diode across the coil; published decay times assume one.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us