SPECIFICATIONS
| Model Number | 326-26-019 |
| Factory Part Number | M326-26-019 |
| Series | Super CB Series |
| Model Size | SCB-6 |
| Ordering Code | SCB-6-CCW-115VAC-3/4″-1 |
| Function | Electrically Actuated Wrap Spring Clutch/Brake Package |
| Voltage | 115 VAC |
| Bore Size | 3/4″ (0.750″) |
| Direction of Rotation | Counterclockwise (CCW) |
| Stop Collar Options | 1-Stop Collar (Standard) |
| Anti-Overrun | Not included |
| Factory Description | CB6SCCW115AC.75B1ST |
| Compatible Power Supply Unit | WSCC-101 (P/N 901-00-014) / WSCC-102 (P/N 901-00-019) |
| Static Torque | 500 lb. in. |
| Max. Anti-Overrun Holding | 300 lb. in. |
| Max. Anti-Back Holding | 300 lb. in. |
| Maximum Speed | 500 RPM |
| Response Time (voltage on, full speed) | 45 ms |
| Weight | 7 lb. |
| Compliance | RoHS Compliant |
| Catalog | Warner Electric Super CB Series Clutch / Brakes Catalog |
SERIES DESCRIPTION
The Warner Electric Super CB Series clutch/brakes function in the same manner as the standard CB Series, with up to five times longer life than a standard unit. Hardened steel wear rings at the crossover points of the clutch, brake and shaft hubs further increase life, making the Super CB the choice for heavy-duty applications requiring maximum torque, high cycle rates and minimum maintenance.
FEATURES
- Maintenance-free self-lubricating hubs are 18% oil by volume.
- Hardened crossover points on input, output and brake hubs provide increased life.
- Hub mounting holes for simple pulley or sprocket mounting.
- Brake engages automatically when de-clutched.
- Single or multi-stop collars available for 360°, 180° or 90° stopping.
SELECTION PROCEDURE
- Step 1: Determine the clutch or brake function—Wrap spring clutches and brakes can perform three control functions: overrunning, start-stop and single revolution. Determine the function that will provide the best control for your application.
- Step 2: Determine the size—To select the correct size unit, determine the maximum RPM at which the clutch or brake will operate and the shaft diameter on which the wrap spring unit will be mounted. Locate the appropriate speed and shaft diameter points on the selection charts.
- Step 3: Verify the design function considerations—Once the appropriate series and model size have been determined, review the design considerations and the checklist of options detailed in the “How to Order” section for each series.
HOW TO ORDER
- Specify Model Configuration: Reference model number 326-26-019 or use ordering code SCB-6-CCW-115VAC-3/4″-1.
- Verify Voltage and Rotation: Confirm your system matches the 115 VAC coil and counterclockwise direction.
Got a Question? We’re Here To Help
- For Manuals, Catalogs & Documentation: See Files Section
- Need More Help? Contact Us