SFM Series Shaft Mounted Clutches


SFM Series VAR 00 | Flange Mounted

CHARACTERISTICS
Electrically operated 12, 24, 103,5 VDC
Single friction face
Activated by power on

UTILISATION
Coupling of a pulley or a hub

PARTICULARITIES
No backlash
For dry use
No residual torque in disengaged position
Fixed OM inductor

ADJUSTMENTS
Airgap “P” should be adjusted at installation
Requires wear compensation

MAINTENANCE MANUAL
SM 304

MOUNTING PRECAUTIONS
Centre the inductor
Observe dimension “M”
Device intended for horizontal or vertical use
POWER SUPPLY

For 24 volts versions only :
CBC 400-24 – CBC 450-24 CBC 500-24 – CBC 550-24 CBC 700 (overexcitation) CBC 140-5 + CBC 140-T (24V) CBC 140-5 (103,5V)

SFM Series Product Data
Reference (Pages 26-27) in catalog CB396r-gb/d-0207

SFM Series VAR 01 | Flange mounted clutch coupling

CHARACTERISTICS
Electrically operated 12, 24, 103,5 VDC
Single friction face
Activated by power on

UTILISATION
Coupling of a pulley or a hub

PARTICULARITIES
No backlash
For dry use
No residual torque in disengaged position
Fixed inductor mounted on ball bearings

ADJUSTMENTS
Airgap “P” should be adjusted at installation
Requires wear compensation

MAINTENANCE MANUAL
SM 304

MOUNTING PRECAUTIONS
The anti-rotation device of the electromagnet shall be inserted in anti rotation slot, with a side play of 0,5 mm and a 1 mm play to the bottom. This avoids a normal stress on the ball-bearings.

We strongly recommend to mount a damping elastic slot in the anti-rotation device in case of vibrations
Device intended for horizontal or vertical use

POWER SUPPLY
For 24 volts versions only : CBC 400-24 – CBC 450-24 CBC 500-24 – CBC 550-24 CBC 700 (overexcitation) CBC 140-5 + CBC 140-T (24V) CBC 140-5 (103,5V)

SFM Series Product Data
Reference (Page 30) in catalog CB396r-gb/d-0207

SFM Series VAR 10 | Bearing mounted

CHARACTERISTICS
Electrically operated 12, 24, 103,5 VDC
Single friction face
Activated by power on

UTILISATION
Coupling of a pulley or a hub

PARTICULARITIES
No backlash
For dry use
No residual torque in disengaged position
Fixed inductor mounted on ball bearings

ADJUSTMENTS
Airgap “P” should be adjusted at installation
Requires wear compensation

MAINTENANCE MANUAL
SM 304

MOUNTING PRECAUTIONS
The anti-rotation device of the electromagnet shall be inserted in anti rotation slot, with a side play of 0,5 mm and a 1 mm play to the bottom. This avoids a normal stress on the ball-bearings.

We strongly recommend to mount a damping elastic slot in the anti-rotation device in case of vibrations
Device intended for horizontal or vertical use

POWER SUPPLY
For 24 volts versions only : CBC 400-24 – CBC 450-24 CBC 500-24 – CBC 550-24 CBC 700 (overexcitation) CBC 140-5 + CBC 140-T (24V) CBC 140-5 (103,5V)

SFM Series Product Data
Reference (Pages 28-29) in catalog CB396r-gb/d-0207

SFM Series VAR 11 | Bearing mounted clutch coupling

CHARACTERISTICS
Electrically operated 12, 24, 103,5 VDC
Single friction face
Activated by power on

UTILISATION
Coupling of a pulley or a hub

PARTICULARITIES
No backlash
For dry use
No residual torque in disengaged position
Fixed OM inductor

ADJUSTMENTS
Airgap “P” should be adjusted at installation
Requires wear compensation

MAINTENANCE MANUAL
SM 304

MOUNTING PRECAUTIONS
Centre the inductor
Observe dimension “M”
Device intended for horizontal or vertical use

POWER SUPPLY
For 24 volts versions only : CBC 400-24 – CBC 450-24 CBC 500-24 – CBC 550-24 CBC 700 (overexcitation) CBC 140-5 + CBC 140-T (24V) CBC 140-5 (103,5V)

Manuals and Specifications


Catalog Warner Electric Clutches and Brakes Catalog 
No products were found matching your selection.