EUM Series Brake Module
Enclosed UniModules Contamination-Proof Design
Enclosed design eliminates damage to the working components.
Totally Enclosed Version
The Enclosed UniModule packages the hardworking components from UM products into a totally enclosed housing. This rugged housing keeps wear particles in and contaminants out and provides quiet operation. Pre-burnished at the factory for rated torque directly out-of-box.
• Keeps contaminants out
• Keeps wear particles in
• Quiet operation
• Finned for heat dissipation
• UL listed when optional conduit box is
installed
To convert any Gen 2 UniModule
50, 100, and 180 sizes to an enclosed model
purchase optional Cover Kit
(part number 5370-101-076)
Enclosed UniModule Conversion
Enclosed UniModules, (EUMs) for 50, 100, and 180 sizes, are being replaced by GEN 2 UniModules (UMs) and an easy to install cover kit. Each kit contains (2) vent covers, (2) gaskets and (4) screws. A vent cover bolts to both sides of the UniModule unit to enclose the open vents of the housing creating a totally enclosed (non-washdown) brake package which keeps contaminants out and wear particles in for clean, quiet operation.
EUM Series
Product Data – Reference (Pages 151-156) in catalog P-1234
EUM SERIES
Model No. | Voltage D.C. | Combined GEN 2 Part No. with kit |
Separate GEN 2 Part No. UniModule |
Separate GEN 2 Part No. Cover Kit |
Original Part No |
EUM-50-20FBB-6 | 90 | 5370-169-260 | 5370-169-983 | ||
EUM-100-20FBB-12 | 90 | 5370-169-260 | 5370-169-989 | ||
EUM-180-20FBB-12 | 90 | 5370-169-262 | 5370-169-995 | ||
EUM-210-20FBB-32 | 90 | 5371-169-078 | |||
EUM-210-20FBB-56 | 90 | 5371-169-082 | |||
EUM-215-20FBB-32 | 90 | 5371-169-086 | |||
EUM-215-20FBB-56 | 90 | 5371-169-090 | |||
EUM-50-20MBFB-6 | 90 | 5370-169-263 | 5370-169-965 | ||
EUM-100-20MBFB-12 | 90 | 5370-169-264 | 5370-169-971 | ||
EUM-180-20MBFB-12 | 90 | 5370-169-265 | 5370-169-977 | ||
EUM-50-20FBB-10 | 90 | 5370-32 | 5370-169-279 | 5370-101-082 | 5370-169-986 |
EUM-100-20FBB-21 | 90 | 5370-33 | 5370-169-284 | 5370-101-082 | 5370-169-992 |
EUM-180-20FBB-21 | 90 | 5370-34 | 5370-169-289 | 5370-101-082 | 5370-169-998 |
EUM-50-20MBFB-10 | 90 | 5370-35 | 5370-169-249 | 5370-101-082 | 5370-169-968 |
EUM-100-20MBFB-21 | 90 | 5370-36 | 5370-169-254 | 5370-101-082 | 5370-169-974 |
EUM-180-20MBFB-21 | 90 | 5370-37 | 5370-169-259 | 5370-101-082 | 5370-169-980 |
EUM-210-7/8-20MBFB-32 | 90 | 5371-169-064 | |||
EUM-210-7/8-20MBFB-56 | 90 | 5371-169-068 | |||
EUM-210-20MBFB-32 | 90 | 5371-169-056 | |||
EUM-210-20MBFB-56 | 90 | 5370-169-060 |
ACCESSORIES
Description | FBB Size | Part No. |
Conduit Box | All Sizes | 5370-101-042 |
Motor Mount Kit for 20FBB |
50/100/180 210/215 |
5370-101-079 5371-101-012 |
Gen2 units are direct replacements for original models
- Changes to the housing fin design increases heat dissipation capacities, especially in the enclosed configuration of the UniModule.
- Improved input to output axis design reduces vibration and improves noise and wear factors.
- Use of custom designed mounting bolts allows for conduit box location directly on top of the unit.
- Bolt hole patterns are re-positioned for ease of mounting.
- Add-on enclosure cover kits allow for a unit to be upgraded to an enclosed unit in the field without replacing the clutch/brake. A cover plate bolts to both sides of the unit creating a completely enclosed brake package, which keeps contaminates out and wear particles in, for clean, quiet operation.
Manuals and Specifications
Catalog | Warner Electric EUM Totally Enclosed Catalog | |
- 5370-169-260
- EUM Series
- Model Size: EUM-50
- Voltage: 90 VDC
- Static Torque: 6 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y
- 5370-169-262
- EUM Series
- Model Size: EUM-180
- Voltage: 90 VDC
- Static Torque: 12 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 182C/143TC 184C/145TC
- 5370-169-263
- EUM Series
- Model Size: EUM-50
- Voltage: 90 VDC
- Static Torque: 6 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y
- 5370-169-264
- EUM Series
- Model Size: EUM-100
- Voltage: 90 VDC
- Static Torque: 12 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y
- 5370-169-265
- EUM Series
- Model Size: EUM-180
- Voltage: 90 VDC
- Static Torque: 12 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 182C/143TC 184C/145TC
- 5370-169-965
- EUM Series
- Model Size: EUM-50
- Voltage: 90 VDC
- Static Torque: 6 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y
- 5370-169-968
- EUM Series
- Model Size: EUM-50
- Voltage: 90 VDC
- Static Torque: 6 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y
- 5370-169-971
- EUM Series
- Model Size: EUM-100
- Voltage: 90 VDC
- Static Torque: 12 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y
- 5370-169-974
- EUM Series
- Model Size: EUM-100
- Voltage: 90 VDC
- Static Torque: 12 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y
- 5370-169-977
- EUM Series
- Model Size: EUM-180
- Voltage: 90 VDC
- Static Torque: 12 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 182C/143TC 184C/145TC
- 5370-169-980
- EUM Series
- Model Size: EUM-180
- Voltage: 90 VDC
- Static Torque: 12 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 182C/143TC 184C/145TC
- 5370-169-983
- EUM Series
- Model Size: EUM-50
- Voltage: 90 VDC
- Static Torque: 6 lb. ft.
- Max RPM: 3600
- NEMA Frame Size: 56C/48Y