Warner Electric Power Supply MCS-805-1 / MCS-805-2

MCS-805-1 / MCS-805-2 Power Supply
The DC voltage required to release the Warner Electric ER-1225 Brake is supplied by the MCS-805-1 or MCS-805-2 Power Supply. The correct brake release voltage— approximately 35-75 volts DC—is set by adjusting the power supply at the time of brake installation. Temperature compensating circuits provide proper operation over the entire operating range of 0°F to 150°F. Switching may be provided on either the AC or DC side of the power supply. The MCS-805-1 may be mounted on its back panel or on 1/2″ conduit. The MCS-805-2 has a torque adjustment capability for soft stop applications. The MCS-805-2 requires two switching circuits when used for those applications requiring soft engagement.

 

MCS-805-1 / MCS-805-2
Model No. Input Output Part No.
MCS-805-1 115/230 VAC, 50/60 Hz +10% 0.4 Amp, 35/75 VDC 6090-448-006
MCS-805-2 115/230 VAC, 50/60 Hz +10% 0.4 Amp, 35/75 VDC 6090-448-007

Click on the links below to see Drawings and Specs:

Warner Electric Clutch and Brake Controls PDF